![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2002/sysdrive-3g3mv-a2002_user-manual_742836018.webp)
1-4
H
International Standards (EC Directives and UL/cUL
Standards)
The 3G3MV Inverter meets the EC Directives and UL/cUL standard requirements for
worldwide use.
Classification
Applicable standard
EC Directives EMC directive
EN50081-2 and EN50082-2
EC Directives
Low-voltage directive prEN50178
UL/cUL
UL508C
H
Compatible with CompoBus/D and RS-422/485
·
Supports RS-422 and RS-485 communications conforming to the MODBUS Commu-
nications Protocol, thus making it possible to easily construct networks with the use of
the Protocol Macro or ASCII Unit mounted on an OMRON SYSMAC PC. The MOD-
BUS Communications Protocol is a trademark of AEG Schneider Automation.
·
Connects to the 3G3MV-PDRT1-SINV CompoBus/D Communications Unit. A remote
I/O function for CompoBus/D communications is available to the 3G3MV Inverter,
which ensures ease of communications just like standard I/O communications.
Furthermore, CompoBus/D communications conform to the DeviceNet communica-
tions protocol for open networks, thus allowing construction of multi-vendor networks
in which other companies’ devices can coexist.
Note
Modbus communication and CompoBus/D communication cannot be performed
simultaneously. It is necessary to select the type of communication required.
H
Handles a Variety of I/O Signals
Handles a variety of I/O signals over a wide application range as described below.
·
Analog voltage input:
0 to 10 V
·
Analog current input:
4 to 20 or 0 to 20 mA
·
Pulse train input:
0.1 to 33.0 kHz
·
Multi-function analog output or pulse train output is selectable as monitor output
H
Suppression of Harmonics
Connects to DC reactors, thus suppressing harmonics more effectively than conven-
tional AC reactors.
Further improvement in the suppression of harmonics is possible with the combined use
of the DC and AC reactors.
Overview
Chapter 1
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...