7-24
7-6 Register Number Allocations in Detail
The following description provides information on register numbers allo-
cated to the Inverter and the meanings of the registers. As for the register
numbers of the parameters (n001 through n179), refer to
Section 10 List of
Parameters
and the description of each of these parameters wherever
explained in this manual.
7-6-1 I/O Function
H
Communications with a Single Slave with Addresses 01 to 32
(01 to 20 Hex)
Read/Write
Register No.
(Hex)
Function
Description
0000
Not used
---
0001
RUN command
Refer to the table below.
0002
Frequency reference
Set the frequency reference in the unit
according to the set value in n152.
0003
V/f gain
Set on condition that 100% is 1000 within a
range from 2.0 to 200.0% (20 to 2000). (see
note 1)
0004 to 0008
Not used
---
0009
Inverter output
Refer to the table below.
000A to 000F
Not used
---
Note 1.
The V/f gain is a rate to be multiplied by the output voltage obtained from V/f
operation. If 1000 (03E8 Hex) is set, the multiplication rate will be 1.
Note 2.
When the above registers are read, values that are set through communica-
tions will be read. For example, when the RUN command (register 0001) is
read, the control input in the register that was previously set through commu-
nications will be returned. This is not a value monitored through the input signal
terminal.
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...