10-20
Para
me-
ter
No.
Ref-
er-
ence
page
Chan-
ges dur-
ing
opera-
tion
Defaul
t set-
ting
Unit
of
set-
ting
Set-
ting
range
Description
Name
Reg-
ister
No.
n098
0162
Overtorque
detection
level
Used to set overtorque detection level.
Detection from output torque: Set in percent-
age based on the rated motor torque as 100%.
Detection from output current: Set in percent-
age based on the rated Inverter output current
as 100%.
30 to
200
1%
160
No
6-36
n099
0163
Overtorque
detection
time
Used to set the detection time of overtorque.
0.1 to
10.0
0.1 s
0.1
No
6-36
n100
0164
UP/DOWN
frequency
selection
Used to store the adjusted frequency reference
with the UP/DOWN function.
0: Frequency not stored
1: Frequency stored
The frequency must be on hold for 5 s or
more.
0, 1
1
0
No
6-48
n101
0165
Speed
search de-
celeration
time
Note
Only applicable for 200/400V,
5.5/7.5kW models
Note
Applicable
for
software
version
No. 010024 or later
0.0 to
10.0
0.1s
2.0
No
---
n102
0166
Speed
search op-
eration lev-
el
Note
Only applicable for 200/400V,
5.5/7.5kW models
Note
Applicable
for
software
version
No. 010024 or later
0 to
200
1%
150
No
---
n103
0167
Torque
compensa-
tion gain
Used to set the gain of the torque compensa-
tion function.
Note
The default setting does not need any
changes in normal operation.
0.0 to
2.5
0.1
1.0
Yes
6-37
n104
0168
Torque
compensa-
tion pri-
mary delay
time con-
stant
Set the response speed of the torque com-
pensation function.
Note
Normally, the default setting does not
need to be changed.
0.0 to
25.5
0.1 s
0.3
No
6-37
n105
0169
Torque
compensa-
tion core
loss
Set the core loss of the motor in use.
Note
Normally, the default setting does not
need to be changed.
Note
This parameter is enabled in V/f control
mode only.
0.0 to
6,550
0.1 W Varies
with
the
capac-
ity.
No
6-38
n106
016A Rated
motor slip
Used to set the rated slip value of the motor in
use.
Note
Used as the constant of the slip com-
pensation function.
0.0 to
20.0
0.1
Hz
Varies
with
the
capac-
ity.
Yes
6-39
n107
016B Motor
phase to
neutral
resistance
Set this parameter to 1/2 of the phase to neu-
tral resistance or phase-to-phase resistance of
the motor.
Note
This parameter is used as a vector con-
trol constant.
0.000
to
65.50
0.001
W
Varies
with
the
capac-
ity
No
5-6
6-2
List of Parameters
Chapter 10
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...