3-4
Power On
FREF (Frequency Reference)
Monitors and sets the frequency reference.
FOUT (Output Frequency)
Monitors the output frequency.
Note
This indicator will be lit by turning the Inverter ON again
if the Inverter is turned OFF while this indicator is lit.
IOUT (Output Current)
Monitors the output current.
Note
This indicator will be lit by turning the Inverter ON again
if the Inverter is turned OFF while this indicator is lit.
MNTR (Multi-function Monitor)
Monitors the values set in U-01 through U-18.
Note
Depending on the inverter capacity, the
number of the Uxx is different.
F/R (Forward/Reverse Rotation)
Selects the direction of rotation.
LO/RE (Local/Remote)
Selects the operation of the Inverter through the Digital
Operator or according to the parameters.
PRGM (Parameter Setting)
Monitors or sets the values in n001 through n179.
The FREF indicator is lit again.
Note
The setting unit of the frequency reference and output frequency is determined by
the set value in n035. The default unit is Hz.
Preparing for Operation and Monitoring
Chapter 3
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...