4-10
5
No-load Operation
·
Start the no-load motor (i.e., not connected to the mechanical system) using the Digital
Operator.
Note
Before operating the Digital Operator, check that the FREQ adjuster is set to MIN.
H
Forward/Reverse Rotation with the Digital Operator
Key
sequence
Indicator
Display
example
Explanation
Monitors the frequency reference.
Press the RUN Key. The RUN Indicator will be lit.
Turn the FREQ adjuster clockwise slowly.
The monitored frequency reference will be
displayed.
The motor will start rotating in the forward direction
according to the frequency reference.
Press the MODE Key to turn ON the F/R indicator.
“For” will be displayed.
Use the Increment or Decrement Key to change the
direction of motor rotation. The direction of motor
rotation selected will be enabled when the display is
changed after the Key is pressed.
·
After changing the frequency reference or the rotation direction, check that there is no
vibration or abnormal sound from the motor.
·
Check that no faults have occurred in the Inverter during operation.
H
Stopping the Motor
·
On completion of operating the motor in the no-load state in the forward or reverse
direction, press the STOP/RESET Key. The motor will stop. (The RUN indicator will
flash until the motor stops.)
6
Actual Load Operation
·
After checking the operation with the motor in no-load status, connect the mechanical
system and operate with an actual load.
Note
Before operating the Digital Operator, check that the FREQ adjuster is set to MIN.
H
Connecting the System
·
After confirming that the motor has stopped completely, connect the mechanical sys-
tem.
·
Be sure to tighten all the screws when fixing the motor axis in the mechanical system.
Test Run
Chapter 4
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...