6-9
n143
Power Averaging Time
Register
018F
Hex
Changes during
operation
No
Setting
range
1 to 200
Unit of
setting
1
(24 ms)
Default setting
1
Set Values
·
Set n143 to the time required to calculate the average of power used in energy-saving
control.
Power averaging time (ms) = Set value in n143 x 24 (ms)
·
Normally, the default setting does not need to be changed.
·
The Inverter averages the power for the set time for energy-saving control.
·
The value set in n143 is used for probe operation. The Inverter in probe operation
changes the voltage at intervals set in this parameter.
·
Increase the set value if the power fluctuates frequently and the Inverter cannot per-
form stable energy control.
n141
Energy-saving Voltage
Lower Limit at 60-Hz Output
Register
018D
Hex
Changes during
operation
No
Setting
range
0 to 120 (%)
Unit of
setting
1%
Default setting
50
n142
Energy-saving Voltage
Upper Limit at 6-Hz Output
Register
018E
Hex
Changes during
operation
No
Setting
range
0 to 25 (%)
Unit of
setting
1%
Default setting
12
Set Values
·
When the output frequency is constant for a certain period while the Inverter is in effec-
tive energy-saving control, the Inverter is set to the primary level of energy-saving con-
trol by n140. Parameter n141 and parameter n142 prevent the output voltage of the
Inverter from dropping excessively so that the motor will not stall or stop at that time.
·
Set the lower limit of output voltage in percentage at each frequency based on the
rated motor voltage as 100%.
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...