![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2002/sysdrive-3g3mv-a2002_user-manual_742836121.webp)
5-22
n126
Frequency Reference 15
Register
017E
Hex
Changes during
operation
Yes
Setting
range
0.00 to max. frequency
Unit of
setting
0.01 Hz
(see
note 1)
Default setting
0.00
n127
Frequency Reference 16
Register
017F
Hex
Changes during
operation
Yes
Setting
range
0.00 to max. frequency
Unit of
setting
0.01 Hz
(see
note 1)
Default setting
0.00
Note 1.
The setting unit of frequency references 1 through 16 is changed with the set
value in n035 for frequency reference setting and decimal place selection. Val-
ues will be set in 0.01-Hz increments if the frequency is less than 100 Hz and
0.1-Hz increments if the frequency is 100 Hz or over.
Note 2.
Frequency reference 1 is enabled with n004 for frequency reference selection
set to 1.
Note 3.
Frequency references 2 through 16 are enabled by setting multi-step speed ref-
erences 1 through 4 in n050 through n056 for multi-function input. Refer to the
following table for the relationship between multi-step speed references 1
through 4 and frequency references 1 through 16.
Frequency reference
Multi-step
speed refer-
ence 1
(Set value: 6)
Multi-step
speed refer-
ence 2
(Set value: 7)
Multi-step
speed refer-
ence 3
(Set value: 8)
Multi-step
speed refer-
ence 4
(Set value: 9)
Frequency reference 1
OFF
OFF
OFF
OFF
Frequency reference 2
ON
OFF
OFF
OFF
Frequency reference 3
OFF
ON
OFF
OFF
Frequency reference 4
ON
ON
OFF
OFF
Frequency reference 5
OFF
OFF
ON
OFF
Frequency reference 6
ON
OFF
ON
OFF
Frequency reference 7
OFF
ON
ON
OFF
Frequency reference 8
ON
ON
ON
OFF
Frequency reference 9
OFF
OFF
OFF
ON
Frequency reference 10 ON
OFF
OFF
ON
Frequency reference 11 OFF
ON
OFF
ON
Frequency reference 12 ON
ON
OFF
ON
Frequency reference 13 OFF
OFF
ON
ON
Frequency reference 14 ON
OFF
ON
ON
Frequency reference 15 OFF
ON
ON
ON
Frequency reference 16 ON
ON
ON
ON
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...