SPEC
2 - 19
MAINTENANCE SPECIFICATIONS
NOTE:
Tighten the rotor nut to 65 Nm (6.5 m · kg, 47 ft · lb), loosen and retighten the rotor nut to 65 Nm
(6.5 m · kg, 47 ft · lb).
Starter relay:
Model/manufacturer
2768090-A/JIDECO
----
Amperage rating
180 A
----
Coil winding resistance
4.2 ~ 4.6
Ω
at 20 ˚C (68 ˚F)
----
Starting circuit cut-off relay:
Model/manufacturer
ACM33221 M06/MATSUSHITA
----
Coil winding resistance
75.69 ~ 92.51
Ω
at 20 ˚C (68 ˚F)
----
Fuse (amperage
×
quantity):
Main fuse
10 A
×
1
----
Reserve fuse
10 A
×
1
----
Part to be tightened
Thread size
Q’ty
Tightening torque
Nm
m·kg
ft·lb
Stator
M5
×
0.8
2
7
0.7
5.1
Holder (AC magneto lead)
M5
×
0.8
2
7
0.7
5.1
Rotor
M12
×
1.25
1
Refer to NOTE.
Neutral switch
M5
×
0.8
2
4
0.4
2.9
Starter motor
M6
×
1.0
2
10
1.0
7.2
Starter relay terminal
M6
×
1.0
2
4
0.4
2.9
Item
Standard
Limit