Applicable indoor units:4-Way Cassette
●
Before proceeding with the installation work, please read carefully through the installation instructions which are provided with the
ceiling panel and the indoor unit and also through the installation instructions which you are now reading. In particular, be absolutely
sure to read through the “Safety Precautions” prior to installation. Also ensure that the user keeps these installation instructions
in a safe place for future reference.
■
The actions which must or must not be taken are described using the following pictographs.
■
The
in
stallat
ion wo
rk
s
hould b
e
e
n
tr
u
ste
d
t
o
the
d
ealer
o
r
the
st
o
re
wh
ere
the
uni
t
w
as
pu
rchase
d o
r
t
o
a
s
p
ec
i
a
liz
e
d
c
on
tract
o
r
,
a
nd
the
uni
t
m
u
st
b
e
in
stalle
d
c
o
rrectly
u
s
ing onl
y
the
s
p
ec
i
f
i
e
d p
arts
wi
t
hou
t
fa
il
.
(Failure to follow this instruction may cause the unit to fall down, water to leak, electric shocks and/or a fire.)
■
Us
ing onl
y
the
d
es
ign
ate
d
ca
bl
es
,
the
wi
r
ing
m
u
st
b
e
c
onn
ecte
d
c
o
rrectly,
a
nd
sec
u
re
d in
s
u
c
h
a
w
ay
that
the
exter
n
al
force of the cables will not be
transmitted to the terminal connections.
(Failure to follow this instruction may cause trouble, heat to be generated and/or a fire.)
■
Ret
u
r
n
the
c
o
vers
p
r
op
erly
t
o
the
i
r
o
r
igin
a
l po
s
i
t
ion
s
whil
e
e
n
s
u
r
ing
that
non
e
o
f
the
wi
res
i
s
pin
che
d o
r
tra
pp
e
d
.
(Failure to follow this instruction may cause electric shocks and/or a fire.)
■
The
uni
t
m
u
st
b
e
in
stalle
d
c
o
rrectly
in
a
lo
cat
ion whi
c
h i
s
str
ong
e
nough
t
o b
ear
the
w
e
igh
t
o
f
a
ll
the
p
arts.
(Failure to follow this instruction may result in injuries caused by the unit falling down.)
■
The
p
arts
s
p
ec
i
f
i
e
d b
y
P
a
n
as
oni
c
m
u
st
b
e
u
se
d
as
the
access
o
ry
p
arts.
(Failure to use the specified parts may cause the unit to fall down and/or water to leak.)
■ The kit must not be installed in a location where flammable gases may
leak in the area around it.
(Failure to follow this instruction may cause ignition if gas should leak and accumulate in the area around the unit.)
These precautions describe instructions which must be followed in order to avoid personal injuries and/or property damage.
■
They describe the instructions using categories which are classified by the extent of the injuries and/or damage caused by incorrect
or improper acts.
These precautions must be observed without fail.
This indicates an action which must be taken
(that is, an action which is mandatory).
CAUTION
This symbol refers to a hazard or
unsafe practice which can result in
personal injury or product or property
damage.
WARNING
This symbol refers to a hazard or
unsafe practice which can result in
severe personal injury or death.
WARNING
This indicates an action which must not
be taken (that is, an action which is prohibited).
■ Do not connect any of the wires from a midway point.
(Failure to follow this instruction may cause defective contact, defective insulation or a current whose level exceeds
what is permissible, resulting in electric shocks and/or a fire.)
■ Do not stow any power cables which have been bundled together using a
tie or other means.
(Failure to follow this instruction may cause heat to be generated and/or a fire.)
Safety Precautions
INSTALLATION INSTRUCTIONS
Air intake chamber
Model No.CZ-FDU3
Select
ing
t
he
D
C
fa
n
m
o
t
or
ta
ps
It is necessary to set the fan speed in accordance with the intended application and the optional parts to be
used if any such part is used. (Table 1-11-1-1-1)
If this speed is not changed, a reduction in the air flow may result, causing the air outlet temperature to drop
and condensation to form during cooling.
There are two ways to set the fan speed: either (1) change the positions of the DIP switches on the indoor unit
control PCB or (2) set the speed using the wired remote controller. Select one of these ways.
* Priority is given to setting the fan speed by changing the positions of the DIP switches.
Indoor unit control PCB
Intended application /
name of optional parts
Setting
No
(1)
Item code
5D/5d
setting data
0001
0000
DC fan motor tap setting table
Standard (factory setting)
High-ceiling setting 1
(with standard, ECONAVI panel)
Air-flow blocking kit
(when a duct is connected.)
Intended application /
name of optional parts
Setting
No
Item code
5D/5d
setting data
(3)
(6)
0003
0006
Air-flow blocking kit (for 3-way air flow)
High-ceiling setting 2
(with standard, ECONAVI panel)
Air-flow blocking kit
(for 2-way air flow)
<Procedure> Be absolutely sure to turn off the
power (earth-leakage circuit breaker).
<1> On Table 1-11-1-1-1, check out the “Setting No.”
that corresponds to the intended application
and the optional parts to be used.
<2> Open the cover of the electrical component box,
and check the indoor unit control PCB.
(Fig. 1-11-1-1-3)
<3> Select the Setting No. which was checked out
on Table 1-11-1-1-1, and change the positions of
the DIP switches on the indoor unit control PCB.
(1) When setting the fan speed by changing
the positions of the DIP switches on the
indoor unit control PCB
(2) When setting the fan speed using a wired remote controller
(optional parts: CZ-RTC5A, CZ-RTC5B
)
“OFF” position
1 2 3
TP6
TP3
TP1
1
ON
2 3
DIP switch
DIP switch
Setting
No.
“OFF” position
“ON” position
DIP switch
“OFF” position
“ON” position
TP6
TP3
TP1
1
ON
2 3
DIP switch
“ON” position
TP6
TP3
TP1
ON
(3)
(6)
(1)
On Table 1-11-1-1-1, check out the “Item code 5D setting data” that corresponds to the
intended application and the optional parts to be used.
(3) When setting the fan speed using a wired remote controller
(optional parts: CZ-RTC4)
On Table 1-11-1-1-1, check out the “Item code 5d setting data” that corresponds to the
intended application and the optional parts to be used.
<1> Hold down the + + buttons together for at least 4 seconds.
The maintenance function screen is displayed.
<2> Use the / buttons to select the display and the / buttons to
select the page.
Select “8.Detailed settings” and press the button.
The [Detailed settings screen] appears.
Using the / buttons, select the unit No.
<3> Using the / buttons, select the item code.
Using the / buttons, change the item code to “5D.”
<4> Using the / buttons, select the setting data.
Using the buttons, change the setting data to the value checked out
on Table 1-11-1-1-1, and press the button.
<5> After selecting the unit No. using the / buttons, press the button.
The [Detailed settings completion screen] appears.
Select “Yes” , and press the .
<1> Hold down the + + buttons together for at least 4 seconds.
<2> Each time the button is pressed, the numbers of the indoor units under group
control are displayed in sequence.
The fan motor of only the indoor unit that has been selected will run.
<3> Specify item code “5d” using the temperature setting / buttons.
<4> Change the setting data using the hour buttons. The setting data details
are as given on Table 1-11-1-1-1.
<5> Press the button. (OK if the display changes from flashing to lighted.)
<6> Press the button. The normal stop status is established.
Go to step <2> to change the selected indoor unit.
<7> Press the button. The normal stop status is established.
(1)
0001
Detailed settings
Unit no.
Code no.
Set data
5D
0001
1-1
20:30 (THU)
Sel.
Next
Unit No.
Setting data
Item code
Detailed settings
Unit no.
Code no.
Set data
0001
1-1
Sel.
Next
20:30 (THU)
5D
Maintenance func
Sel.
20:30 (THU)
Page [
] Confirm
5. Sensor info.
6. Servicing check
7. Simple settings
8. Detailed settings
<Procedure> Ensure that the units have stopped operating before changing the fan speed.
<Procedure> Ensure that the unit has stopped operating before changing the fan speed.
■
Panasonic disclaims all liability for any accidents or damages occurring as a result of installing the kit using any procedures which
are not described in the installation instructions or which do not use the specified parts.Any malfunctioning or trouble caused
by the manner in which the kit was installed will not be covered by the terms and conditions of the product warranty.
■
Usage precautions
• Install this Air intake chamber on the indoor unit before proceeding to install the indoor unit itself.
• During installation, handle this Air intake chamber very carefully since subjecting its sides to impacts may result in damage.
• Keep these installation instructions in a safe place together with the operating instructions of the indoor unit
.
NOTES
CAUTION
Table 1-1
1
-1-1-
1
Fig. 1-11-1-1-3
TP6
TP3
TP1
1
ON
2 3
TP6
TP3
TP1
1 2 3
SW001
Setting example
1: OFF
2: OFF
ON
3: ON
SM830283-00_欧州向け R32シングル36-71形TD&SM.indb 37
20/01/30 10:25:25
Содержание S-3650PF3E
Страница 20: ...19 MEMO SM830283 00_欧州向け R32シングル36 71形TD SM indb 19 2020 01 29 21 46 03 ...
Страница 178: ... MEMO 1 13 5 SM830283 00_欧州向け R32シングル36 71形TD SM indb 5 20 01 30 10 26 09 ...
Страница 198: ... MEMO 2 4 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 19 52 20 ...
Страница 204: ... MEMO 3 2 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 20 01 28 11 25 46 ...
Страница 270: ... MEMO 5 4 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 21 17 57 ...
Страница 272: ... MEMO 6 1 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 20 10 15 08 ...
Страница 294: ... MEMO 7 21 SM830283 00_欧州向け R32シングル36 71形TD SM indb 21 20 01 28 11 22 25 ...
Страница 321: ...202001 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 23 9 32 11 ...