background image

Operating Instructions 

Air Conditioner

ENGLISH

 

Before operating the unit, read these operating instructions thoroughly and 

keep them for future reference.

Panasonic Corporation

1006 Kadoma, Kadoma City, Osaka, Japan

WEB-ACXF55-28650-EN

Wall Mounted

 (Type K3)

Model No.

INDOOR UNIT

Wall Mounted

 (Type K3)

S-3650PK3E

S-6010PK3E

OUTDOOR UNIT

Single Split  

See page 12.

OI_00_321038_EN.indb   1

2020/10/27   10:53:15

Содержание K3

Страница 1: ...ructions thoroughly and keep them for future reference Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan WEB ACXF55 28650 EN Wall Mounted Type K3 Model No INDOOR UNIT Wall Mounted Type K3 S 36...

Страница 2: ...comfortable room conditions Use this only for its intended purpose as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using...

Страница 3: ...s must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint cord...

Страница 4: ...or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children...

Страница 5: ...recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By...

Страница 6: ...rating Instructions attached to the Remote Controller The flap display on the remote controller differs from the actual flap angle A Model No CZ RTC4 For all indoor units Read the Operating Instructio...

Страница 7: ...stened with water Air filters Air filters cleaning is needed every two weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under the shade a...

Страница 8: ...gations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptable...

Страница 9: ...environment or operating hours mold proliferation or inhibition of mold growth will be changed NOTES z z The internal drying operation is not activated when connecting other than the wired remote con...

Страница 10: ...the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Airflow direction cannot be changed When air discharge temperature is low during heating operat...

Страница 11: ...bleshooting z z Stop the operation immediately and turn the power off Then contact your dealer and report the serial number and symptom You also report if the inspection mark and the letters E F H L P...

Страница 12: ...heating performance reduces as outside temperature decreases In the event that heating is not sufficient please use an additional heating appliance Defrosting z z This appliance may start defrosting o...

Страница 13: ...035 0 060 0 060 0 075 Sound pressure level High dB A 35 38 40 47 47 49 Medium dB A 31 34 36 44 44 45 Low dB A 27 30 32 40 40 41 Sound power level High dB A 51 54 56 63 63 65 Medium dB A 47 50 52 60 6...

Страница 14: ...Cooling Heating dB A 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 99 99 99 Europe Model Name U 71PZH2E8 U 100PZH2E8 U 125PZH...

Страница 15: ...ooling mode 10 C 43 C DB Heating mode 15 C 24 C DB Europe Model Name U 100PZ2E8 U 125PZ2E8 U 140PZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 9 0 12 5 14 0 BTU h 30 700 42 700 47 800 H...

Страница 16: ...ooling Heating dB A 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 65 98 98 98 Europe Model Name U 71PZH3E8 U 100PZH3E8 U 125PZH3E...

Страница 17: ...Power source 220 230 240 V 50 Hz 380 400 415 V 3N 50 Hz Cooling capacity kW 9 0 12 5 14 0 9 0 12 5 14 0 BTU h 30 700 42 700 47 800 30 700 42 700 47 800 Heating capacity kW 9 0 12 5 14 0 9 0 12 5 14 0...

Страница 18: ...onic com Panasonic Corporation 2020 WEB ACXF55 28650 EN DC0920 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany OI_00_32...

Отзывы: