1
1-11-1-1-36
2
1.Accessory parts
2.Mounting procedure
1
4
4
Before proceeding with the mounting, remove the cushions which have been inserted into the air outlets (in 4 places).
<1> Mounting Air intake chamber (Fig. 1)
• Place the black sealant side of Air intake chamber toward the indoor unit.
(Air intake chamber can be mounted correctly in only one way so ensure that the shapes of the indoor unit and chamber
are aligned properly.)
• Use the accessory screws (x4) to secure the indoor unit and
Air intake chamber.
<2> Installing the indoor unit
• Install the indoor unit with Air intake chamber mounted on it to the ceiling.
(Now proceed with the installation in accordance with the installation instructions provided with the indoor unit.)
<3> Mounting the ceiling panel (Fig. 2)
• Mount the ceiling panel to the indoor unit (with Air intake chamber).
(For details on how the ceiling panel is to be mounted, refer to the installation instructions which are provided
with the ceiling panel.)
<4> Connecting the panel cables (Fig. 2)
• Remove the cover of Air intake chamber, and remove the cover of electrical component box.
•
Cut the clamp used to bundle the ceiling panel cable, insert the 22
P c
onnector (white) of the cable into the through-hole
in Air intake chamber, and connect it to the 22P connector inside the electrical component box.
•
Re
turn the cover of electrical component bo
x
and the cover of Air intake chamber to their original positions.
The accessory parts are required for the installation work so they should not be discarded until the work is completed.
●
The following parts are provided inside the package so check that they are accounted for.
Part name
Part name
Part name
Washers
Screws
(5 x 40)
No. of
parts
No. of
parts
No. of
parts
(Used to secure this
Air intake chamber)
(Used to secure this
Air intake chamber)
Installation instructions
Air intake chamber
Screws
Washers
Black sealant
Indoor unit
(Fig. 1)
Clamp
Ceiling panel
22P cable connector
(white)
Fig. 1-11-1-1-2
Mounting procedure (continued)
Air intake chamber
Indoor unit
Electrical component box
Cover
Through-hole for 22P
cable connector (white)
SM830283-00_欧州向け R32シングル36-71形TD&SM.indb 36
20/01/30 10:25:25
Содержание S-3650PF3E
Страница 20: ...19 MEMO SM830283 00_欧州向け R32シングル36 71形TD SM indb 19 2020 01 29 21 46 03 ...
Страница 178: ... MEMO 1 13 5 SM830283 00_欧州向け R32シングル36 71形TD SM indb 5 20 01 30 10 26 09 ...
Страница 198: ... MEMO 2 4 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 19 52 20 ...
Страница 204: ... MEMO 3 2 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 20 01 28 11 25 46 ...
Страница 270: ... MEMO 5 4 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 21 17 57 ...
Страница 272: ... MEMO 6 1 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 20 10 15 08 ...
Страница 294: ... MEMO 7 21 SM830283 00_欧州向け R32シングル36 71形TD SM indb 21 20 01 28 11 22 25 ...
Страница 321: ...202001 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 23 9 32 11 ...