High-spec Wired Remote Controller CZ-RTC5B
Display of "maintenance function" screen
1 Keep pressing the
,
and
buttons simultaneously for 4 or more seconds.
The “Maintenance func” screen appears on the
LCD display.
2 Press the
or
button to see each
menu.
If you wish to see the next screen instantly, press
the
or
button.
Sel
Sel.
Maintenance func 20:30 (THU)
Page [
] Confirm
1. Outdoor unit error data
2. Service contact
3. RC setting mode
4. Test run
Fig. 7-7
List of Servicing Functions
Functions
Description
Menu selection
Reset operation
Unit status
Test run
Operation with forced
thermostat ON
4. Test run
Press the
button.
Sensor temperature
display
Temperature display from
each sensor
5. Sensor info
Servicing check
display
Alarm history display
6. Service check
Simple settings
Filter lifetime, operating
mode priority, central control
address, and other settings
7. Simple settings
Press the
button.
(Restart)
When settings are
made from a remote
controller, the indoor
unit where that
remote controller is
connected stops.
Detailed settings
System address, indoor
unit address, central control
address, and other settings
8. Detailed settings
Auto address
Auto address setting based
on command from the wired
remote controller
9. Auto address
Automatic reset
Entire system stops.
7-8. Test Run Function
Operates the unit with the thermostat forced ON.
<Procedure of CZ-RTC5B>
1 Keep pressing the
,
and
buttons simultaneously for 4 or more seconds.
The “Maintenance func” screen appears on the
LCD display.
2 Press the
or
button to see each
menu.
If you wish to see the next screen instantly, press
the
or
button.
Select "4. Test run" on the LCD display and press
the
button.
Change the display from OFF to ON by pressing
the
or
button. Then press the
button.
Fig. 7-8
Fig. 7-9
3 Press the
button. “TEST” will be displayed
on the LCD display.
4 Press the
button. Test run will be started.
Test run setting mode screen appears on the LCD
display.
CZ-RTC5B
CZ-RTC4
<Procedure of CZ-RTC4>
1 Press and hold the
button for 4 seconds or
longer.
2 “
” appears on the remote controller LCD
display (Fig. 7-9).
3
4 Press the
button to return to normal remote
controller display.
Press the
button to start the test run.
A
°
°
Maintenance func
Sel.
20:30 (THU)
1. Outdoor unit error data
2. Service contact
3. RC setting mode
4. Test run
Page [
] Confirm
Maintenance func
Sel.
Page [
] Confirm
20:30 (THU)
1. Outdoor unit error data
2. Service contact
3. RC setting mode
4. Test run
[
] Confirm
Test run
Change
20:30 (THU)
Test run
ON
20:30 (THU)
[ ] START
TEST
[ ] START
20:30 (THU)
TEST
FAN SPEED
FLAP
20:30 (THU)
COOL
DE
TEST
MO
7-17
SM830283-00_欧州向け R32シングル36-71形TD&SM.indb 17
20/01/28 11:22:23
Содержание S-3650PF3E
Страница 20: ...19 MEMO SM830283 00_欧州向け R32シングル36 71形TD SM indb 19 2020 01 29 21 46 03 ...
Страница 178: ... MEMO 1 13 5 SM830283 00_欧州向け R32シングル36 71形TD SM indb 5 20 01 30 10 26 09 ...
Страница 198: ... MEMO 2 4 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 19 52 20 ...
Страница 204: ... MEMO 3 2 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 20 01 28 11 25 46 ...
Страница 270: ... MEMO 5 4 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 21 17 57 ...
Страница 272: ... MEMO 6 1 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 20 10 15 08 ...
Страница 294: ... MEMO 7 21 SM830283 00_欧州向け R32シングル36 71形TD SM indb 21 20 01 28 11 22 25 ...
Страница 321: ...202001 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 23 9 32 11 ...