5-2-2-16
5
P16 DC Peak Detection
DC current peak due to compressor failure.
DC current peak due to defective power transistor(s).
DC current peak due to defective outdoor unit PCB.
DC current peak due to short circuit.
Malfunction Decision Conditions
During startup and operation of cooling and heating, when inverter DC peak data is received by the outdoor internal
DC Peak sensing circuitry.
Malfunction Caused
Troubleshooting
SM830283-00_欧州向け R32シングル36-71形TD&SM.indb 16