1-1-1-1-1
1
1
Single - Type
1-1. Unit Specifications
PZ3
1. 4-Way Cassette Type S-3650PU3E(36) / U-36PZ3E5
INDOOR
MODEL
S-3650PU3E(36)
-
-
PANEL
MODEL
Standard type : CZ-KPU3 or CZ-KPU3W / ECONAVI type : CZ-KPU3A or CZ-KPU3AW
-
-
OUTDOOR
MODEL
-
U-36PZ3E5
-
Branch pipe
MODEL
-
Performance test condition
ISO5151 / EN14511 / EN12102 / EN14825
Power supply
Ø, Hz
1Ø 50Hz
1Ø 50Hz
V
220V
230V
240V
220V
230V
240V
Min
Max
C
O
O
L
I
N
G
Capacity
kW
3.6
3.6
3.6
-
-
-
1.5
4.0
BTU/h
12300
12300
12300
-
-
-
5100
13600
Current
A
-
-
-
3.85
3.70
3.55
-
-
Input power
W
-
-
-
-
-
-
-
-
TOTAL W
-
0.830k
0.830k
0.830k
0.255k
1.050k
Annual consumption
TOTAL kWh *
4
-
-
-
-
415
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
4.34
4.34 / A
4.34
5.88
3.81
ErP
*
6
Pdesign
kW
-
-
-
-
3.6
-
-
-
SEER
(W/W)
-
-
-
-
8.1
-
-
-
Annual consumption
kWh
-
-
-
-
156
-
-
-
Class
-
-
-
-
A++
-
-
-
Power factor
%
-
-
-
98
98
98
-
-
Noise indoor *
7
dB-A (H/M/L)
30 / 28 / 27
-
-
-
Power Level dB
45 / 43 / 42
-
-
-
Noise outdoor
dB-A (H/L)
-
46 / -
-
-
Power Level dB
-
64 / -
-
-
H
E
A
T
I
N
G
Capacity
kW
3.6
3.6
3.6
-
-
-
1.5
4.6
BTU/h
12300
12300
12300
-
-
-
5100
15700
Current
A
-
-
-
3.35
3.20
3.05
-
-
Input power
W
-
-
-
-
-
-
-
-
TOTAL W
-
0.710k
0.710k
0.710k
0.230k
1.060k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
5.07
5.07 / A
5.07
6.52
4.34
ErP
*
6
Pdesign at -10°C
kW
-
-
-
-
2.8
-
-
-
Tbivalent
°C
-
-
-
-
-10
-
-
-
SCOP
(W/W)
-
-
-
-
4.8
-
-
-
Annual consumption
kWh
-
-
-
-
817
-
-
-
elbu(-10°C)
kW
-
-
-
-
0.00
-
-
-
Class
-
-
-
-
A++
-
-
-
Power factor
%
-
-
-
97
97
97
-
-
Noise indoor *
7
dB-A (H/M/L)
30 / 28 / 27
-
-
-
Power Level dB
45 / 43 / 42
-
-
-
Noise outdoor
dB-A (H/L)
-
47 / -
-
-
Power Level dB
-
66 / -
-
-
LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
-
-
-
Max Current(A) / Max Input power(W)
-
-
-
8.90 / 1.95k
8.90 / 1.99k
8.90 / 2.04k
-
Starting current(A) (Cooling/Heating)
-
-
-
3.85 / 3.35
3.70 / 3.20
3.55 / 3.05
-
Comp output(W)
-
1.10k
1.10k
1.10k
-
Time Delay fuse max size(A)
-
15
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
60
40
-
Moisture removal volume
L/h
0.7 (0.7 ×1)
-
-
External static pressure
Pa
-
-
-
Indoor
Air flow
*
7
Cooling
m³/min (H/M/L)
14.5 / 13.0 / 11.5
-
-
-
Heating
m³/min (H/M/L)
14.5 / 13.0 / 11.5
-
-
-
Outdoor
Air flow
Cooling
m³/min
-
33.6
-
-
Heating
m³/min
-
34.0
-
-
Refrigerant type / amount(ship) k
g
/ amount(max) k
g
-
R32
0.870
0.950
-
F-Gas
GWP /
CO2eq (ton) (PRECHARGED AMOUNT) /
CO2eq (ton) (MAXIMUM CHARGED AMOUNT)
-
675
0.59
0.64
-
Product dimension
Height
mm
256
619
-
Width
mm
840
824
-
Depth
mm
840
299
-
Product dimension (Panel)
H×W×D
mm
33.5 × 950 × 950
-
-
Packing dimension
Height
mm
302
680
-
Width
mm
898
958
-
Depth
mm
898
416
-
Weight
(NET)
k
g
19
32
-
(GROSS)
k
g
25
35
-
Panel (NET)
k
g
5
-
-
Layers limit (actually)
11 (12)
5 (6)
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-10°C ~ 43°C
-
Heat (DBT)
16°C ~ 30°C
-15°C ~ 24°C
-
Max Working Pressure HP/LP MPa
4.15 / 2.55
-
P
I
P
I
N
G
Pipe port diameter mm (inch)
(Liquid)Ø6.35(1/4) (Gas)Ø12.7(1/2)
(Liquid)Ø6.35(1/4) (Gas)Ø12.7(1/2)
-
Pipe diameter mm (inch)
(Liquid)Ø6.35(1/4) (Gas)Ø12.7(1/2)
-
Connecting method
flared type
flared type
-
Standard length m
5 m
-
Pipe length range m
3 ~ 15 m
-
Indoor unit & Outdoor unit height difference m
15 m(OD located lower) / 15 m(OD located higher)
-
Add gas amount
g
/m
10
g
/m
-
Pipe length for additional gas m
7.5 m
-
* In the case of nanoe X OFF
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m³/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 230V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6
SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season, Other fiche data indicates in an attached sheet.
*7 H : High at setting 5 stage (Level 5), M : Middle at setting 5 stage (Level 3), L : Low at setting 5 stage (Level 1)
SM830283-00_欧州向け R32シングル36-71形TD&SM.indb 1
20/01/30 10:24:31
Содержание S-3650PF3E
Страница 20: ...19 MEMO SM830283 00_欧州向け R32シングル36 71形TD SM indb 19 2020 01 29 21 46 03 ...
Страница 178: ... MEMO 1 13 5 SM830283 00_欧州向け R32シングル36 71形TD SM indb 5 20 01 30 10 26 09 ...
Страница 198: ... MEMO 2 4 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 19 52 20 ...
Страница 204: ... MEMO 3 2 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 20 01 28 11 25 46 ...
Страница 270: ... MEMO 5 4 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 21 17 57 ...
Страница 272: ... MEMO 6 1 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 20 10 15 08 ...
Страница 294: ... MEMO 7 21 SM830283 00_欧州向け R32シングル36 71形TD SM indb 21 20 01 28 11 22 25 ...
Страница 321: ...202001 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 23 9 32 11 ...