3. If desired, (re-)configure the PLL divider settings.
4. Setting the restart lock detection bit PLL_CON.RESLD = 1
5. Waiting until the PLL VCO part becomes locked (PLL_CON.LOCK = 1)
6. When the LOCK is set again, the Prescaler Mode can be deselected (PLL_CON.VCOBYP = 0) and normal PLL
operation is resumed.
7. Clear the PLL loss-of-lock NMI flag FNMIPLL.