User Manual
655
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
LIN Transceiver
LIN Transceiver Interrupt Enable Register
RES
10
r
Reserved
Always read as 0
OT_SC
9
w
LIN Receiver Overtemperature Status Clear
0
B
NO_Clear
, overtemperature not cleared
1
B
Clear
, overtemperature cleared
M_SM_ERR_S
C
8
w
LIN Transceiver Mode Error - Slope Mode Error Status Clear
0
B
NO_Clear
, overtemperature not cleared
1
B
Clear
, overtemperature cleared
RES
7
r
Reserved
Always read as 0
TXD_TMOUT_
ISC
6
w
LIN TXD time-out Interrupt Status Clear
0
B
NO_Clear
, no time-out cleared
1
B
Clear
, time-out cleared
OC_ISC
5
w
LIN Receiver Overcurrent Interrupt Status Clear
0
B
NO_Clear
, overcurrent status not cleared
1
B
Clear
, overcurrent status cleared
OT_ISC
4
w
LIN Receiver Overtemperature Interrupt Status / Status Clear
0
B
NO_Clear
, overtemperature not cleared
1
B
Clear
, overtemperature cleared
M_SM_ERR_I
SC
3
w
LIN Transceiver Mode Error - Slope Mode Error Interrupt Status
Clear
0
B
NO_Clear
, overtemperature not cleared
1
B
Clear
, overtemperature cleared
RES
2:0
r
Reserved
Always read as 1
Table 346 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
0000 0000
H
RESET_TYPE_3
LIN_IRQEN
Offset
Reset Value
LIN Transceiver Interrupt Enable Register
0C
H
see
Field
Bits
Type
Description