User Manual
592
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Capture/Compare Unit 6 (CCU6)
Register TCTR2 controls the single-shot and the synchronization functionality of both timers T12 and T13.
Both timers can run in single-shot mode. In this mode, they stop their counting sequence automatically after
one counting period with a count value of zero. The single-shot mode and the synchronization feature of T13
to T12 allow the generation of events with a programmable delay after well-defined PWM actions of T12. For
example, this feature can be used to trigger AD conversions, after a specified delay (to avoid problems due to
switching noise), synchronously to a PWM event.
CCU6_TCTR2
Offset
Reset Value
Timer Control Register 2
58
H
see
Field
Bits
Type
Description
RES
15:12
r
Reserved
Returns 0 if read.
T13RSEL
11:10
rw
Timer T13 External Run Selection
Bit field T13RSEL defines the event of signal T13HR that can set the
run bit T13R by hardware.
00
B
Disabled
, The external setting of T13R is disabled.
01
B
Rising edge
, Bit T13R is set if a rising edge of signal T13HR is
detected.
10
B
Falling edge
, Bit T13R is set if a falling edge of signal T13HR is
detected.
11
B
Edge
, Bit T13R is set if an edge of signal T13HR is detected.
T12RSEL
9:8
rw
Timer T12 External Run Selection
Bit field T12RSEL defines the event of signal T12HR that can set the
run bit T12R by hardware.
00
B
Disabled
, The external setting of T12R is disabled.
01
B
Rising edge
, Bit T12R is set if a rising edge of signal T12HR is
detected.
10
B
Falling edge
, Bit T12R is set if a falling edge of signal T12HR is
detected.
11
B
Edge
, Bit T12R is set if an edge of signal T12HR is detected.
RES
7
r
Reserved
Returns 0 if read.
15
12
r
RES
11
10
rw
T13RSEL
9
8
rw
T12RSEL
77
r
RES
6
5
rw
T13TED
4
2
rw
T13TEC
11
rw
T13SSC
00
rw
T12SSC