User Manual
180
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
System Control Unit - Digital Modules (SCU-DM)
Peripheral Input Select Register 1
SCU_MODPISEL1
Offset
Reset Value
Peripheral Input Select Register 1
0BC
H
Field
Bits
Type
Description
RES
31:8
r
Reserved
Returns 0 if read; should be written with 0.
T21EXCON
7
rw
Timer 21 External Input Control
0
B
Timer 21 Input T21EX is selected by bit field
SCU_MODPISEL2.T21EXIS.
1
B
Timer 21 Input T21EX is connected to signal from
CCU6 (Output >cc6_ch0).
T2EXCON
6
rw
Timer 2 External Input Control
0
B
Timer 2 Input T2EX is selected by bit field
SCU_MODPISEL2.T2EXIS.
1
B
Timer 2 Input T2EX is connected to signal from CCU6
(Output >cc6_cout60).
RES
5:4
r
Reserved
Returns 0 if read; should be written with 0.
RES
3:1
r
Reserved
Returns 0 if read; should be written with 0.
XTAL12EN
0
rwpw
Pins XTAL1/2 Enable Bit
This is a PASSWD protected bit. When the protection
scheme (see
) is activated (default), this bit
cannot be written directly.
Note:
this bit is RESET_TYPE_4
0
B
Pins XTAL1/2 is not available. This setting overrides
the OSC_CON.XPD setting.
1
B
Pins XTAL1/2 is available.
31
16
r
RES
15
8
r
RES
77
rw
T21E
XCON
66
rw
T2EX
CON
5
4
r
RES
3
1
r
RES
00
rwpw
XTAL