User Manual
865
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
10-Bit Analog Digital Converter (ADC1)
Lower Comparator Trigger Level Channel 0-3
ADC1_TH0_3_LOWER
Offset
Reset Value
Lower Comparator Trigger Level Channel 0-
3
40
H
see
Field
Bits
Type
Description
CH3_LOW
31:24
rw
Channel 3 lower trigger level
00
H
, Min. threshold value
FF
H
, Max. threshold value
CH2_LOW
23:16
rw
Channel 2 lower trigger level
00
H
, Min. threshold value
FF
H
, Max. threshold value
CH1_LOW
15:8
rw
Channel 1 lower trigger level
00
H
, Min. threshold value
FF
H
, Max. threshold value
CH0_LOW
7:0
rw
Channel 0 lower trigger level
00
H
, Min. threshold value
FF
H
, Max. threshold value
Table 469 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
1D2F 423A
H
RESET_TYPE_4
31
24
rw
CH3_LOW
23
16
rw
CH2_LOW
15
8
rw
CH1_LOW
7
0
rw
CH0_LOW