User Manual
42
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Power Management Unit (PMU)
6.3.5
PMU Register Overview
The registers are addressed wordwise.
6.3.6
Register Definition
The registers are addressed wordwise.
6.3.6.1
Power Supply Generation Register
The following register is dedicated to control the voltage regulators VDDP, VDDC. It provides an overview
about the status of the two voltage supplies.
Voltage Reg Status Register
The PMU_SUPPLY_STS register shows the overvoltage and overload condition of VDDP and VDDC. To use this
information as interrupt sources it must be selected explicitly in this register.
Table 7
Register Address Space for PMU Registers
Module
Base Address
End Address
Note
PMU
50004000
H
50004FFF
H
Power Management Unit
Registers
SCUPM
50006000
H
50006FFF
H
Power Management Unit
Registers
Table 8 Register
Overview
Register Short Name
Register Long Name
Offset Address
Reset Value
,
Power Supply Generation Register
Voltage Reg Status Register
008
H
0000 0000
H
,
VDDEXT Control
00C
H
0000 0000
H
PMU_SUPPLY_STS
Offset
Reset Value
Voltage Reg Status Register
008
H
see