User Manual
236
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
System Control Unit - Power Modules (SCU-PM)
LIN_FAIL_IS
6
r
LIN Fail Interrupt Status
Note:
This flag is an OR combination of LIN_OC_IS and
LIN_OT_IS
0
B
INACTIVE
, no status set
1
B
ACTIVE
, at least one status set
RES
5:4
r
Reserved
Always read as 0
HS2_FAIL_IS
3
r
High Side Driver 2 Fail Interrupt Status
Note:
This flag is an OR combination of HS2_OC_IS,
HS2_OT_IS and HS2_OL_IS
0
B
INACTIVE
, no status set
1
B
ACTIVE
, at least one status set
HS1_FAIL_IS
2
r
High Side Driver 1 Fail Interrupt Status
Note:
This flag is an OR combination of HS1_OC_IS,
HS1_OT_IS and HS1_OL_IS
0
B
INACTIVE
, no status set
1
B
ACTIVE
, at least one status set
LS2_FAIL_IS
1
r
Low Side Driver 2 Fail Interrupt Status
Note:
This flag is an OR combination of LS2_OC_IS,
LS2_OT_IS, LS2_OT_PREWARN_IS and LS2_OL_IS
0
B
INACTIVE
, no status set
1
B
ACTIVE
, at least one status set
LS1_FAIL_IS
0
r
Low Side Driver 1 Fail Interrupt Status
Note:
This flag is an OR combination of LS1_OC_IS,
LS1_OT_IS, LS1_OT_PREWARN_IS and LS1_OL_IS
0
B
INACTIVE
, no status set
1
B
ACTIVE
, at least one status set
Table 126 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
00000000
H
RESET_TYPE_4
Field
Bits
Type
Description