User Manual
245
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
System Control Unit - Power Modules (SCU-PM)
8.5
Power Control Unit for Power Modules (PCU_PM)
The chapter describes the implementation of the power modules state machine. This state machine is
responsible for powering up and powering down the on-board power modules. It takes care about the
interaction between the Measurement Unit and the modules which are evaluated by the Unit. The following
modules are controlled by this statemachine:
Analog Modules controlled by Power Control Unit:
• Central Reference Voltage Generation
• Central Bias Current Generation
• 8-Bit ADC Core
• Supply Voltage Attenuators
• Monitoring Inputs Voltage Attenuators
• LIN Transceiver
• Low Side Drivers
• High Side Drivers
VBAT_UV_IE
0
rw
VBAT Undervoltage Interrupt Enable
0
B
Interrupt is disabled
1
B
Interrupt is enabled
Table 131 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
000000FF
H
RESET_TYPE_4
Field
Bits
Type
Description