User Manual
43
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Power Management Unit (PMU)
Field
Bits
Type
Description
RES
31:7
r
Reserved
Always read as 0
PMU_5V_FAIL_EN
6
rw
Enabling of VDDP status information as interrupt
source
0
B
No interrupts are generated
1
B
Interrupts are generated
PMU_5V_OVERLOAD
5
r
Overload at VDDP regulator
Note:
if this flag is set and an additional filter time
of 290 us (typ.) is passed the system will be
put to sleep mode. This flag is automatically
cleared, if error condition is removed.
0
B
No overload
1
B
Overload
PMU_5V_OVERVOLT
4
r
Overvoltage at VDDP regulator
Note:
This flag is automatically cleared, if error
condition is removed.
0
B
No overvoltage
1
B
Overvoltage
RES
3
r
Reserved
Always read as 0
PMU_1V5_FAIL_EN
2
rw
Enabling of VDDC status information as interrupt
source
0
B
No interrupts are generated
1
B
Interrupts are generated
31
16
r
RES
15
7
r
RES
66
rw
PMU_
5V_F
AIL*
55
r
PMU_
5V_O
VER*
44
r
PMU_
5V_O
VER*
33
r
RES
22
rw
PMU_
1V5_
FAI*
11
r
PMU_
1V5_
OVE*
00
r
PMU_
1V5_
OVE*