10-Bit Analog Digital Converter (ADC1)
Lower Comparator Trigger Level Channel 4-7
ADC1_TH4_7_LOWER
Offset
Reset Value
Lower Comparator Trigger Level Channel 4-
7
44
H
see
Field
Bits
Type
Description
CH7_LOW
31:24
rw
Channel 7 lower trigger level
00
H
, Min. threshold value
FF
H
, Max. threshold value
CH6_LOW
23:16
rw
Channel 6 lower trigger level
00
H
, Min. threshold value
FF
H
, Max. threshold value
CH5_LOW
15:8
rw
Channel 5 lower trigger level
00
H
, Min. threshold value
FF
H
, Max. threshold value
CH4_LOW
7:0
rw
Channel 4 lower trigger level
00
H
, Min. threshold value
FF
H
, Max. threshold value
Table 470 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
0000 0000
H
RESET_TYPE_4
31
24
rw
CH7_LOW
23
16
rw
CH6_LOW
15
8
rw
CH5_LOW
7
0
rw
CH4_LOW