User Manual
869
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
10-Bit Analog Digital Converter (ADC1)
Lower Counter Trigger Level Channel 0-3
ADC1_CNT0_3_LOWER
Offset
Reset Value
Lower Counter Trigger Level Channel 0-3
D8
H
see
Field
Bits
Type
Description
RES
31:29
r
Reserved
Always read as 0
HYST_LO_CH3
28:27
rw
Channel 3 lower hysteresis
0
H
HYSTOFF
, hysteresis switched off
1
H
HYST4
, hysteresis = 4
2
H
HYST8
, hysteresis = 8
3
H
HYST16
, hysteresis = 16
CNT_LO_CH3
26:24
rw
Lower timer trigger threshold channel 3
0
H
, 1 measurement
1
H
, 2 measurements
2
H
, 4 measurements
3
H
, 8 measurements
4
H
, 16 measurements
5
H
, 32 measurements
6
H
, 63 measurements
7
H
, 63 measurements
RES
23:21
r
Reserved
Always read as 0
HYST_LO_CH2
20:19
rw
Channel 2 lower hysteresis
0
H
HYSTOFF
, hysteresis switched off
1
H
HYST4
, hysteresis = 4
2
H
HYST8
, hysteresis = 8
3
H
HYST16
, hysteresis = 16
31
29
r
RES
28
27
rw
HYST_LO
_CH3
26
24
rw
CNT_LO_CH3
23
21
r
RES
20
19
rw
HYST_LO
_CH2
18
16
rw
CNT_LO_CH2
15
13
r
RES
12
11
rw
HYST_LO
_CH1
10
8
rw
CNT_LO_CH1
7
5
r
RES
4
3
rw
HYST_LO
_CH0
2
0
rw
CNT_LO_CH0