User Manual
248
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
System Control Unit - Power Modules (SCU-PM)
8.5.2
Power Control Unit Register
The PCU is fully controllable by the below listed SFR Registers.
The registers are addressed wordwise.
Power Control Unit Control Status Register
Table 132 Register
Overview
Register Short Name
Register Long Name
Offset
Address
Reset Value
Power Control Unit Register
SCUPM_PCU_CTRL_STS
Power Control Unit Control Status Register
30
H
0EE37EF3
H
Package Configuration Register 1
90
H
00000100
H
SCUPM_PCU_CTRL_STS
Offset
Reset Value
Power Control Unit Control Status Register
30
H
see
Field
Bits
Type
Description
RES
31:28
r
Reserved
Always read as 0
RES
27:18
r
Reserved
Always read as 0
RES
17
r
Reserved
Always read as 0
RES
16:9
r
Reserved
Always read as 0
31
28
r
RES
27
18
r
RES
17
17
r
RES
16
16
r
RES
15
9
r
RES
88
rw
LIN_
VS_U
V_S*
7
6
r
RES
55
r
RES
4
2
r
RES
11
rw
CLKW
DT_S
D_D*
00
r
RES