User Manual
714
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Measurement Core Module (incl. ADC2)
23.5.2
Calibration Unit Control Registers
The Calibration Unit can be configured by the
SFR
Register shown below. The registers which cannot be
written by the user have the attribute
rwp
. This register is:
The registers are addressed wordwise.
ADC2 Calibration Value Channel 0 & 1
Table 380 Register
Overview
Register Short Name
Register Long Name
Offset Address
Reset Value
Calibration Unit Control Registers
Calibration for Channel 0 & 1
34
H
0000 0000
H
Calibration for Channel 2 & 3
38
H
0000 0000
H
Calibration for Channel 4 & 5
3C
H
0000 0000
H
Calibration for Channel 6 & 7
40
H
0000 0000
H
ADC2_CAL_CH0_1
Offset
Reset Value
Calibration for Channel 0 & 1
34
H
see
Field
Bits
Type
Description
GAIN_CH1
31:24
rwpt
Gain Calibration for channel 1
For ADC output set CALIB_EN_1 = 0
RES
23:21
r
Reserved
Always read as 0
OFFS_CH1
20:16
rwpt
Offset Calibration for channel 1
For ADC output set CALIB_EN_1 = 0
GAIN_CH0
15:8
rwpt
Gain Calibration for channel 0
For ADC output set CALIB_EN_0 = 0
RES
7:5
r
Reserved
Always read as 0
31
24
rwpt
GAIN_CH1
23
21
r
RES
20
16
rwpt
OFFS_CH1
15
8
rwpt
GAIN_CH0
7
5
r
RES
4
0
rwpt
OFFS_CH0