User Manual
686
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Measurement Unit
Temperature Sensor Control Register
MF_TEMPSENSE_CTRL
Offset
Reset Value
Temperature Sensor Control Register
10
H
see
Field
Bits
Type
Description
RES
31:10
r
Reserved
Always read as 0
RES
9:8
r
Reserved
Always read as 0
SYS_OT_STS
7
r
System Overtemperature (MU) Status
0
B
INACTIVE
, write clears status
1
B
ACTIVE
, interrupt status set
SYS_OTWARN_STS
6
r
System Overtemperature Warning (MU) Status
0
B
INACTIVE
, write clears status
1
B
ACTIVE
, interrupt status set
LS_OT_STS
5
r
Low Side Overtemperature (MU) Status
0
B
INACTIVE
, write clears status
1
B
ACTIVE
, interrupt status set
LS_OTWARN_STS
4
r
Low Side Overtemperature Warning (MU) Status
0
B
INACTIVE
, write clears status
1
B
ACTIVE
, interrupt status set
RES
3:0
r
Reserved
Always read as 0
Table 363 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
00000003
H
RESET_TYPE_4
31
16
r
RES
15
10
r
RES
9
8
r
RES
77
r
SYS_
OT_*
66
r
SYS_
OTW*
55
r
LS_O
T_S*
44
r
LS_O
TWA*
3
0
r
RES