User Manual
47
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Power Management Unit (PMU)
VDDEXT Control
PMU_VDDEXT_CTRL
Offset
Reset Value
VDDEXT Control
00C
H
Field
Bits
Type
Description
RES
31:14
r
Reserved
Always read as 0
VDDEXT_OT_SC
13
w
VDDEXT Supply Overtemperature Status clear
1
B
VDDEXT Overtemperature status cleared
0
B
VDDEXT Overtemperature status not cleared
VDDEXT_UV_ISC
12
w
VDDEXT Supply Undervoltage Interrupt Status clear
1
B
VDDEXT Undervoltage cleared
0
B
VDDEXT Undervoltage not cleared
VDDEXT_OT_ISC
11
w
VDDEXT Supply Overtemperature Interrupt Status
clear
1
B
VDDEXT Overtemperature cleared
0
B
VDDEXT Overtemperature not cleared
RES
10:8
r
Reserved
Always read as 0
VDDEXT_STABLE
7
r
VDDEXT Supply Stable
0
B
VDDEXT not in stable condition
1
B
VDDEXT in stable condition
VDDEXT_OT
6
r
VDDEXT Supply Overtemperature
0
B
VDDEXT not in overtemperature condition
1
B
VDDEXT in overtemperature condition
VDDEXT_OT_STS
5
r
VDDEXT Supply Overtemperature Status
0
B
VDDEXT not in overtemperature condition
1
B
VDDEXT in overtemperature condition
VDDEXT_UV_IS
4
r
VDDEXT Supply Undervoltage Interrupt Status
0
B
VDDEXT not in undervoltage condition
1
B
VDDEXT in undervoltage condition
VDDEXT_OT_IS
3
r
VDDEXT Supply Overtemperature Interrupt Status
0
B
VDDEXT no overtemperature condition
1
B
VDDEXT overtemperature condition
31
16
r
RES
15
14
r
RES
13
13
w
VDDE
XT_*
12
12
w
VDDE
XT_*
11
11
w
VDDE
XT_*
10
8
r
RES
77
r
VDDE
XT_*
66
r
VDDE
XT_*
55
r
VDDE
XT_*
44
r
VDDE
XT_*
33
r
VDDE
XT_*
22
rw
VDDE
XT_*
11
rw
VDDE
XT_*
00
rw
VDDE
XT_*