User Manual
578
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Capture/Compare Unit 6 (CCU6)
DTE0
8
rw
Dead-Time Enable Bit 0
Bit DTE0 enables and disables the dead-time generation for
compare channel 0 of timer T12.
0
B
Disabled
, Dead-time generation is disabled. The
corresponding outputs switch from the passive state to the
active state (according to the actual compare status) without
any delay.
1
B
Enabled
, Dead-time generation is enabled. The corresponding
outputs switch from the passive state to the active state
(according to the compare status) with the delay programmed
in bit field DTM.
DTM
7:0
rw
Dead-Time
Bit field DTM determines the programmable delay between
switching from the passive state to the active state of the selected
outputs. The switching from the active state to the passive state is
not delayed.
Table 306 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
0000
H
RESET_TYPE_3
Field
Bits
Type
Description