System Control Unit - Digital Modules (SCU-DM)
Baud Rate Timer/Reload Register, Low Byte 2
SCU_BGL2
Offset
Reset Value
Baud Rate Timer/Reload Register, Low Byte
2
09C
H
see
Field
Bits
Type
Description
RES
31:5
r
Reserved
Returns 0 if read; should be written with 0.
BG2_FD_SEL
4:0
rw
Fractional Divider Selection
Selects the fractional divider to be n/32, where n is the
value of FD_SEL and is in the range of 0 to 31.
For example, writing 0001
B
to FD_SEL selects the
fractional divider to be1/32.
Note:
Fractional divider has no effect if BR_VALUE =
000
H
.
Table 103 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
0000 0000
H
RESET_TYPE_3
31
16
r
RES
15
5
r
RES
4
0
rw
BG2_FD_SEL