User Manual
674
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
High-Speed Synchronous Serial Interface SSC1/SSC2
REN
9
rw
Receive Error Enable
Can only be accessed when EN=0 (programming mode).
Invalid data when EN=1 (operating mode).
0
B
IGNORE
, receive errors.
1
B
CHECK
, receive errors.
TEN
8
rw
Transmit Error Enable
Can only be accessed when EN=0 (programming mode).
Invalid data when EN=1 (operating mode).
0
B
IGNORE
, transmit errors.
1
B
CHECK
, transmit errors.
LB
7
rw
Loop Back Control
Can only be accessed when EN=0 (programming mode).
Invalid data when EN=1 (operating mode).
0
B
NORMAL
, output.
1
B
LB
, Receive input is connected with transmit output
(half-duplex mode).
PO
6
rw
Clock Polarity Control
Can only be accessed when EN=0 (programming mode).
Invalid data when EN=1 (operating mode).
0
B
LOW
, Idle clock line is low, leading clock edge is low-
to-high transition.
1
B
HIGH
, Idle clock line is high, leading clock edge is
high-to-low transition.
PH
5
rw
Clock Phase Control
Can only be accessed when EN=0 (programming mode).
Invalid data when EN=1 (operating mode).
0
B
SHIFT
, transmit data on the leading clock edge,
latch on trailing edge.
1
B
LATCH
, receive data on leading clock edge, shift on
trailing edge.
HB
4
rw
Heading Control
Can only be accessed when EN=0 (programming mode).
Invalid data when EN=1 (operating mode).
0
B
LSB
, Transmit/Receive LSB First.
1
B
MSB
, Transmit/Receive MSB First.
BM
3:0
rw
Data Width Selection
Can only be accessed when EN=0 (programming mode).
Invalid data when EN=1 (operating mode).
0000
B
Reserved. Do not use this combination.
0001
B
-
1111
B
Transfer Data Width is 2 … 16 bits (BM+1).
Table 353 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
00000000
H
RESET_TYPE_3
Field
Bits
Type
Description