User Manual
199
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
System Control Unit - Digital Modules (SCU-DM)
T2_SUSP
3
rw
Timer2 Debug Suspend Bit
0
B
Timer2 will not be suspended.
1
B
Timer2 will be suspended.
T13SUSP
2
rw
Timer 13 Debug Suspend Bit
When suspended, additionally the T13 PWM output is set
to inactive level.
0
B
Timer 13 in Capture/Compare Unit will not be
suspended.
1
B
Timer 13 in Capture/Compare Unit will be
suspended.
T12SUSP
1
rw
Timer 12 Debug Suspend Bit
When suspended, additionally the T12 PWM outputs are
set to inactive level and capture inputs are disabled.
0
B
Timer 12 in Capture/Compare Unit will not be
suspended.
1
B
Timer 12 in Capture/Compare Unit will be
suspended.
RES
0
r
Reserved
Returns 0 if read; should be written with 0.
Table 99 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
0000 0081
H
RESET_TYPE_3
Field
Bits
Type
Description