User Manual
797
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
10-Bit Analog Digital Converter (ADC1)
Measurement Unit 1 Calibration for Channel 6 & 7
ADC1_CAL_CH6_7
Offset
Reset Value
Calibration for Channel 6 & 7
54
H
see
Field
Bits
Type
Description
CALGAIN_CH7
31:24
rw
Gain Calibration for channel 7
For ADC output set CALIB_EN_7 = 0
RES
23:21
r
Reserved
Always read as 0
CALOFFS_CH7
20:16
rw
Offset Calibration for channel 7
For ADC output set CALIB_EN_7 = 0
CALGAIN_CH6
15:8
rw
Gain Calibration for channel 6
For ADC output set CALIB_EN_6 = 0
RES
7:5
r
Reserved
Always read as 0
CALOFFS_CH6
4:0
rw
Offset Calibration for channel 6
For ADC output set CALIB_EN_6 = 0
Table 432 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
0000 0000
H
RESET_TYPE_4
31
24
rw
CALGAIN_CH7
23
21
r
RES
20
16
rw
CALOFFS_CH7
15
8
rw
CALGAIN_CH6
7
5
r
RES
4
0
rw
CALOFFS_CH6