User Manual
765
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
10-Bit Analog Digital Converter (ADC1)
Measurement Unit 1 Control Register 3
ADC1_CTRL3
Offset
Reset Value
Measurement Unit 1 Control Register 3
18
H
see
Field
Bits
Type
Description
RES
31:20
r
Reserved
Always read as 0
SAMPLE_TIME_LVCH
19:16
rw
Sample time of ADC1
Note:
the asolute sampling time of a Low Voltage
Channel should not be choosen lower than 80 ns.
Otherwise it is not ensured that the settling time
of the input signal is long enough.
0
H
MICLK4
, 4 ADC1_CLK clock periods(default)
1
H
MICLK6
, 6 ADC1_CLK clock periods
2
H
MICLK8
, 8 ADC1_CLK clock periods
3
H
MICLK10
, 10 ADC1_CLK clock periods
4
H
MICLK12
, 12 ADC1_CLK clock periods
5
H
MICLK14
, 14 ADC1_CLK clock periods
6
H
MICLK16
, 16 ADC1_CLK clock periods
7
H
MICLK18
, 18 ADC1_CLK clock periods
8
H
MICLK20
, 20 ADC1_CLK clock periods
9
H
MICLK22
, 22 ADC1_CLK clock periods
A
H
MICLK12
, 12 ADC1_CLK clock periods
B
H
MICLK12
, 12 ADC1_CLK clock periods
C
H
MICLK12
, 12 ADC1_CLK clock periods
D
H
MICLK12
, 12 ADC1_CLK clock periods
E
H
MICLK12
, 12 ADC1_CLK clock periods
F
H
MICLK12
, 12 ADC1_CLK clock periods
RES
15:12
r
Reserved
Always read as 0
31
20
r
RES
19
16
rw
SAMPLE_TIME_L
VCH
15
12
r
RES
11
8
rw
SAMPLE_TIME_H
VCH
77
r
MCM_
RDY
66
r
EoC_
FAIL
55
r
RES
44
w
EoC_
FAI*
3
2
r
RES
11
rw
SW_M
ODE
00
rw
MCM_
PD_N