General Purpose Timer Units (GPT12)
16.4.8.3 Encoding
Encoding of Timer Count Direction Control
Timer Mode and Gated Timer Mode: Encoding of Overall Prescaler Factor
Counter Mode: Encoding of Input Edge Selection
Table 263 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
00000000
H
RESET_TYPE_3
Table 264 GPT2 Timer Count Direction Control
Pin TxEUD
Bit TxUDE
Bit TxUD
Count Direction
X
0
0
Count Up
X
0
1
Count Down
0
1
0
Count Up
1
1
0
Count Down
0
1
1
Count Down
1
1
1
Count Up
Table 265 GPT2 Overall Prescaler Factors for Internal Count Clock (Timer Mode and Gated Timer
Mode)
Individual Prescaler
for Tx
Common Prescaler for Module Clock
1)
1) Please note the non-linear encoding of bitfield BPS2.
BPS2 = 01
B
BPS2 = 00
B
BPS2 = 11
B
BPS2 = 10
B
TxI = 000
B
2
4
8
16
TxI = 001
B
4
8
16
32
TxI = 010
B
8
16
32
64
TxI = 011
B
16
32
64
128
TxI = 100
B
32
64
128
256
TxI = 101
B
64
128
256
512
TxI = 110
B
128
256
512
1024
TxI = 111
B
256
512
1024
2048
Table 266 GPT2 Auxiliary Timer T5 Input Edge Selection (Counter Mode)
T5I
Triggering Edge for Counter Increment/Decrement
X00
B
None. Counter T5 is disabled
001
B
Positive transition (rising edge) on T5IN
010
B
Negative transition (falling edge) on T5IN
011
B
Any transition (rising or falling edge) on T5IN