User Manual
760
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
10-Bit Analog Digital Converter (ADC1)
24.4
ADC - Trigger Unit
The DPP Unit provides also a trigger block. This trigger block provides the following functionality:
• “Exceptional Interrupt Measurement” (EIM), upon hardware event , the channel programmed in
is inserted after the current measurement is finished. Afterwards the current sequence
will be continued with the next measurement from the current sequence.
• “Exceptional Sequence Measurement“ (ESM), upon hardware event , the sequence programmed in
is inserted after the current measurement is finished. After the sequence (up to 12
measurements) exception is finished the next measurement from the interrupted sequence is selected.
After the Exceptional Sequence Measurement is finished an interrupt is issued.
• “Software Mode”, in Software Mode the control of the Channel Controller (Sequencer) is disabled, instead
the conversions are fully controlled by software. During Software Mode EIM and ESM hardware events are
ignored.