User Manual
854
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
10-Bit Analog Digital Converter (ADC1)
Upper Comparator Trigger Level Channel 4-7
ADC1_TH4_7_UPPER
Offset
Reset Value
Upper Comparator Trigger Level Channel 4-
7
CC
H
see
Field
Bits
Type
Description
CH7_UP
31:24
rw
Channel 7 upper trigger level
00
H
, min. threshold value = 0
FF
H
, max. threshold value = 255
CH6_UP
23:16
rw
Channel 6upper trigger level
00
H
, min. threshold value = 0
FF
H
, max. threshold value = 255
CH5_UP
15:8
rw
Channel 5 upper trigger level
00
H
, min. threshold value = 0
FF
H
, max. threshold value = 255
CH4_UP
7:0
rw
Channel 4 upper trigger level
00
H
, min. threshold value = 0
FF
H
, max. threshold value = 255
Table 462 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
0000 0000
H
RESET_TYPE_4
31
24
rw
CH7_UP
23
16
rw
CH6_UP
15
8
rw
CH5_UP
7
0
rw
CH4_UP