User Manual
856
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
10-Bit Analog Digital Converter (ADC1)
Upper Comparator Trigger Level Differential Channel 1-4
ADC1_DCHTH1_4_UPPER
Offset
Reset Value
Upper Comparator Trigger Level Differential
Channel 1-4
D4
H
see
Field
Bits
Type
Description
DCH4_UP
31:24
rw
Differential Channel 4 upper trigger level
00
H
, min. threshold value = 0
FF
H
, max. threshold value = 255
DCH3_UP
23:16
rw
Differential Channel 3 upper trigger level
00
H
, min. threshold value = 0
FF
H
, max. threshold value = 255
DCH2_UP
15:8
rw
Differential Channel 2 upper trigger level
00
H
, min. threshold value = 0
FF
H
, max. threshold value = 255
DCH1_UP
7:0
rw
Differential Channel 1 upper trigger level
00
H
, min. threshold value = 0
FF
H
, max. threshold value = 255
Table 464 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_4
0000 0000
H
RESET_TYPE_4
31
24
rw
DCH4_UP
23
16
rw
DCH3_UP
15
8
rw
DCH2_UP
7
0
rw
DCH1_UP