User Manual
920
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
10-Bit Analog Digital Converter (ADC1)
24.12
Postprocessing Default Values
The following table shows the assigned measurements of the particular channels and the reset default values
which are configured by FW during power-up. Since all channels are configurable by the user, the reset values
can be reconfigured by writting the corresponding registers.
Table 489 Channel
allocation
and postprocessing default settings (effective after reset)
Chan
nel#
Name
Function
MMO
DE
1)
1) Register MMODE0_11; 0 = range control, 1 = UV, 2 = OV
FILTCO
EFF
2)
2) Register FILTCOEFF0_11; 0 = 1/2, 1 = 1/4, 2 = 1/8, 3 = 1/16
Threshold
digital
3)
3) Bitfield CHn_UP / CHn_LOW
Threshol
d analog
Hyster
esis
4)
4) Bitfield HYST_UP_CHn / HYST_LO_CHn; 0 = hyst off, 1 = hyst 4, 2 = hyst 8, 3 = hyst 16
Coun
ters
5)
5) Bitfield CNT_UP_CHn / CNT_LO_CHn; 0 = 1 meas., 1 = 2 meas., 2 = 4 meas., 3 = 8 meas.
Ch. 0 VBAT_SEN
SE
VBAT_SENSE
0
3
upper C0
H
19.27V
3
2
lower 3A
H
5.79V
2
2
Ch. 1 VS
VS supply voltage
0
3
upper C5
H
19.78V
3
3
lower 42
H
6.59V
2
3
Ch. 2 MON1
MON1
0
3
upper FF
H
30.87V
0
3
lower 00
H
0V
0
3
Ch. 3 MON2
MON2
0
3
upper FF
H
30.87V
0
2
lower 00
H
0V
0
2
Ch. 4 MON3
MON3
0
3
upper FF
H
30.87V
0
0
lower 00
H
0V
0
0
Ch. 5 MON4
MON4
0
3
upper FF
H
30.87V
0
0
lower 00
H
0V
0
0
Ch. 6 MON5/
P2.0
MON5 or P2.0 (device
variant dependant)
0
3
upper FF
H
30.87V /
5.50V
0
0
lower 00
H
0V
0
0
Ch. 7 P2.1
P2.1
0
3
upper FF
H
5.50V
0
0
lower 00
H
0V
0
0
Ch. 8 P2.2
P2.2
0
3
upper FF
H
5.50V
0
0
lower 00
H
0V
0
0
Ch. 9 P2.3
P2.3
0
3
upper FF
H
5.50V
0
0
lower 00
H
0V
0
0
Ch10 P2.6
P2.6
0
3
upper FF
H
5.50V
0
0
lower 00
H
0V
0
0
Ch11 P2.7
P2.7
0
3
upper FF
H
5.50V
0
0
lower 00
H
0V
0
0