TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
High-Voltage Monitor Input
The following tables provide an overview of the configuration possibilities on the MON_INs via
XSFR
.
includes all pull-up and pull-down setup scenarios which can be chosen for one MONx.
shows an overview of the available states of a MONx.
Table 490 Pull-Up / Pull-Down Input Current
MONx_PU
MONx_PD
Output Current Description
0
0
leakage current
1)
1) all current sources switched off.
pull-up/down current source disabled
0
1
pull-down
pull-down current source enabled (for low active switches)
1
0
pull-up
pull-up current source enabled (for high active switches)
1
1
switchable
2)
2) will be automatically switched by the MONx circuit depending on level of input signal.
pull-up/down depending on input voltage
Table 491 MONx_EN MON Mode definition
MONx_EN
Mode
Description
0
disabled
Monitoring input is disabled (no wake-up possible!)
1
normal mode
/power saving
mode
Monitoring input is active during device Normal Mode Monitoring
input automatically automatically enters power saving mode in
device Sleep Mode and Stop Mode