User Manual
106
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
System Control Unit - Digital Modules (SCU-DM)
7.3.6.2
PLL Registers
These registers control the PLL configuration or settings.
PLL Control Register
SCU_PLL_CON
Offset
Reset Value
PLL Control Register
044
H
Field
Bits
Type
Description
RES
31:12
r
Reserved
Returns 0 if read; should be written with 0.
UNPROT_VCOBYP
11
w
Unprotect write access of VCO_BYP
Writing this Bit within an write access of VCO_BYP will
overtake the provided value to VCO_BYP without
protection
Note: Read is always ‘0’
UNPROT_OSCDISC
10
w
Unprotect write access of OSC_DISC
Writing this Bit within an write access of OSCDISC will
overtake the provided value to OSCDISC without
protection
Note: Read is always ‘0’
RES
9:8
r
Reserved
Returns 0 if read; should be written with 0.
31
16
r
RES
15
12
r
RES
11
11
w
UNPR
OT_*
10
10
w
UNPR
OT_*
9
8
r
RES
7
4
rwpw
NDIV
33
rw
VCOB
YP
22
rw
OSCD
ISC
11
rw
RESL
D
00
r
LOCK