User Manual
929
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
High-Voltage Monitor Input
Settings Monitor 5
Table 494 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_2
47474747
H
RESET_TYPE_2
PMU_MON_CNF2
Offset
Reset Value
Settings Monitor 5
038
H
see
Field
Bits
Type
Description
RES
31:8
r
Reserved
Always read as 0
MON5_STS
7
r
MON5 Status Input
Note:
MONx_STS is not updated, when MONx_EN
is switched off. MONx_STS is also not
updated, when both wake-options
(MONx_RISE and MONx_FALL) are off
0
B
MON input has low status
1
B
MON input has high status
RES
6
r
Reserved
Always read as 1
MON5_PU
5
rw
Pull-Up Current Source for MON5 Input Enable
Note:
Works only if MON5_EN is enabled
0
B
Pull-up source disabled
1
B
Pull-up source enabled
MON5_PD
4
rw
Pull-Down Current Source for MON5 Input Enable
Note:
Works only if MON1_EN is enabled
0
B
Pull-down source disabled
1
B
Pull-down source enabled
31
16
r
RES
15
8
r
RES
77
r
MON5
_STS
66
r
RES
55
rw
MON5
_PU
44
rw
MON5
_PD
33
rw
MON5
_CYC
22
rw
MON5
_RI*
11
rw
MON5
_FA*
00
rw
MON5
_EN