User Manual
926
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
High-Voltage Monitor Input
MON3_STS
23
r
MON3 Status Input
Note:
MONx_STS is not updated, when MONx_EN
is switched off. MONx_STS is also not
updated, when both wake-options
(MONx_RISE and MONx_FALL) are off
0
B
MON input has low status
1
B
MON input has high status
RES
22
r
Reserved
Always read as 1
MON3_PU
21
rw
Pull-Up Current Source for MON3 Input Enable
Note:
Works only if MON3_EN is enabled
0
B
Pull-up source disabled
1
B
Pull-up source enabled
MON3_PD
20
rw
Pull-Down Current Source for MON3 Input Enable
Note:
Works only if MON3_EN is enabled
0
B
Pull-down source disabled
1
B
Pull-down source enabled
MON3_CYC
19
rw
MON3 for Cycle Sense Enable
Note:
Works only if MON3_EN is enabled
0
B
Cycle Sense disabled
1
B
Cycle Sense enabled
MON3_RISE
18
rw
MON3 Wake-up on Rising Edge Enable
Note:
Works only if MON3_EN is enabled
0
B
Wake-up disabled
1
B
Wake-up enabled
MON3_FALL
17
rw
MON3 Wake-up on Falling Edge Enable
Note:
Works only if MON3_EN is enabled
0
B
Wake-up disabled
1
B
Wake-up enabled
MON3_EN
16
rw
MON3 Enable
0
B
MON3 disabled
1
B
MON3 enabled
Field
Bits
Type
Description