Microcontroller with LIN and Power Switches for Automotive Applications
High-Voltage Monitor Input
MON2_STS
15
r
MON2 Status Input
Note:
MONx_STS is not updated, when MONx_EN
is switched off. MONx_STS is also not
updated, when both wake-options
(MONx_RISE and MONx_FALL) are off
0
B
MON input has low status
1
B
MON input has high status
RES
14
r
Reserved
Always read as 1
MON2_PU
13
rw
Pull-Up Current Source for MON2 Input Enable
Note:
Works only if MON2_EN is enabled
0
B
Pull-up source disabled
1
B
Pull-up source enabled
MON2_PD
12
rw
Pull-Down Current Source for MON2 Input Enable
Note:
Works only if MON2_EN is enabled
0
B
Pull-down source disabled
1
B
Pull-down source enabled
MON2_CYC
11
rw
MON2 for Cycle Sense Enable
Note:
Works only if MON2_EN is enabled
0
B
Cycle Sense disabled
1
B
Cycle Sense enabled
MON2_RISE
10
rw
MON2 Wake-up on Rising Edge Enable
Note:
Works only if MON2_EN is enabled
0
B
Wake-up disabled
1
B
Wake-up enabled
MON2_FALL
9
rw
MON2 Wake-up on Falling Edge Enable
Note:
Works only if MON2_EN is enabled
0
B
Wake-up disabled
1
B
Wake-up enabled
MON2_EN
8
rw
MON2 Enable
0
B
MON2 disabled
1
B
MON2 enabled
Field
Bits
Type