User Manual
928
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
High-Voltage Monitor Input
MON1_STS
7
r
MON1 Status Input
Note:
MONx_STS is not updated, when MONx_EN
is switched off. MONx_STS is also not
updated, when both wake-options
(MONx_RISE and MONx_FALL) are off
0
B
MON input has low status
1
B
MON input has high status
RES
6
r
Reserved
Always read as 1
MON1_PU
5
rw
Pull-Up Current Source for MON1 Input Enable
Note:
Works only if MON1_EN is enabled
0
B
Pull-up source disabled
1
B
Pull-up source enabled
MON1_PD
4
rw
Pull-Down Current Source for MON1 Input Enable
Note:
Works only if MON1_EN is enabled
0
B
Pull-down source disabled
1
B
Pull-down source enabled
MON1_CYC
3
rw
MON1 for Cycle Sense Enable
Note:
Works only if MON1_EN is enabled
0
B
Cycle Sense disabled
1
B
Cycle Sense enabled
MON1_RISE
2
rw
MON1 Wake-up on Rising Edge Enable
Note:
Works only if MON1_EN is enabled
0
B
Wake-up disabled
1
B
Wake-up enabled
MON1_FALL
1
rw
MON1 Wake-up on Falling Edge Enable
Note:
Works only if MON1_EN is enabled
0
B
Wake-up disabled
1
B
Wake-up enabled
MON1_EN
0
rw
MON1 Enable
0
B
MON1 disabled
1
B
MON1 enabled
Field
Bits
Type
Description