User Manual
489
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
General Purpose Timer Units (GPT12)
16.4.8.4 GPT2 Timer and CAPREL Interrupt Control Registers
The Interrupt control register for GPT2 and CAPREL are located in the SCU.
101
B
Positive transition (rising edge) of T6 toggle latch T6OTL
110
B
Negative transition (falling edge) of T6 toggle latch T6OTL
111
B
Any transition (rising or falling edge) of T6 toggle latch T6OTL
Table 267 GPT2 Core Timer T6 Input Edge Selection (Counter Mode)
T6I
Triggering Edge for Counter Increment/Decrement
000
B
None. Counter T6 is disabled
001
B
Positive transition (rising edge) on T6IN
010
B
Negative transition (falling edge) on T6IN
011
B
Any transition (rising or falling edge) on T6IN
1XX
B
Reserved. Do not use this combination
Table 266 GPT2 Auxiliary Timer T5 Input Edge Selection (Counter Mode)
(cont’d)
T5I
Triggering Edge for Counter Increment/Decrement