User Manual
61
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Power Management Unit (PMU)
VDDEXT_UV
18
rh
Wake VDDEXT Undervoltage
Note:
this register is cleared automatically by
read operation
0
B
No wake-up detected
,
1
B
wake-up detected
,
VDDEXT_OT
17
rh
Wake VDDEXT Overtemperature
Note:
this register is cleared automatically by
read operation
0
B
No wake-up detected
,
1
B
wake-up detected
,
RES
16:13
r
Reserved
Always read as 0
MON5_WAKE_STS
12
rh
Status of MON5
Note:
this register is cleared automatically by
read operation. The user has to clear this
flag before entering power saving modes
otherwise the device will stay in active
0
B
No wake-up detected
,
1
B
wake-up detected
,
MON4_WAKE_STS
11
rh
Status of MON4
Note:
this register is cleared automatically by
read operation. The user has to clear this
flag before entering power saving modes
otherwise the device will stay in active
0
B
No wake-up detected
,
1
B
wake-up detected
,
MON3_WAKE_STS
10
rh
Status of MON3
Note:
this register is cleared automatically by
read operation. The user has to clear this
flag before entering power saving modes
otherwise the device will stay in active
0
B
No wake-up detected
,
1
B
wake-up detected
,
Field
Bits
Type
Description