User Manual
571
Rev. 1.1
2019-03-18
TLE984xQX
Microcontroller with LIN and Power Switches for Automotive Applications
Capture/Compare Unit 6 (CCU6)
Timer T12 Counter Register
Register T12 represents the counting value of timer T12. It can only be written while the timer T12 is stopped.
Write actions while T12 is running are not taken into account. Register T12 can always be read by software.
In edge-aligned mode, T12 only counts up, whereas in center-aligned mode, T12 can count up and down.
MSEL60
3:0
rw
Capture/Compare Mode Selection
These bit fields select the operating mode of the three timer T12
capture/compare channels. Each channel (n = 0, 1, 2) can be
programmed individually either for compare or capture operation
according to:
0000
B
Compare outputs disabled
, Compare outputs disabled, pins
CC6n and COUT6n can be used for I/O. No capture action.
0001
B
Pin CC6n, pin COUT6n
, Compare output on pin CC6n, pin
COUT6n can be used for I/O. No capture action.
0010
B
Pin COUT6n, Pin CC6n
, Compare output on pin COUT6n, pin
CC6n can be used for I/O. No capture action.
0011
B
Pins COUT6n and CC6n
, Compare output on pins COUT6n and
CC6n.
01XX
B
Double-Register Capture modes
.
1000
B
Hysteresis-like mode
, see
. In order to enable the hall
edge detection, all three MSEL6x must be programmed to Hall
Sensor mode.
1001
B
Hysteresis-like mode
.
101X
B
Multi-Input Capture modes
, see
11XX
B
Multi-Input Capture modes
, see
Table 297 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
0000
H
RESET_TYPE_3
CCU6_T12
Offset
Reset Value
Timer T12 Counter Register
78
H
see
Field
Bits
Type
Description
T12CV
15:0
rwh
Timer T12 Counter Value
This register represents the lower 8-bit counter value of timer T12.
Field
Bits
Type Description
15
0
rwh
T12CV