Capture/Compare Unit 6 (CCU6)
Timer T12 Period Register
Register T12PR contains the period value for timer T12. The period value is compared to the actual counter
value of T12 and the resulting counter actions depend on the defined counting rules. This register has a
shadow register and the shadow transfer is controlled by bit STE12. A read action by software delivers the
value which is currently used for the compare action, whereas the write action targets a shadow register. The
shadow register structure allows a concurrent update of all T12-related values.
Capture/Compare Register for Channel CC60
In compare mode, the registers CC60R is the actual compare registers for T12. The values stored in CC60R are
compared (all three channels in parallel) to the counter value of T12. In capture mode, the current value of the
T12 counter register is captured by registers CC60R if the corresponding capture event is detected.
Table 298 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
0000
H
RESET_TYPE_3
CCU6_T12PR
Offset
Reset Value
Timer T12 Period Register
24
H
see
Field
Bits
Type Description
T12PV
15:0
rwh
T12 Period Value
The value T12PV defines the counter value for T12, which leads to a
period-match. On reaching this value, the timer T12 is set to zero
(edge-aligned mode) or changes its count direction to down
counting (center-aligned mode).
Table 299 RESET
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
0000
H
RESET_TYPE_3
CCU6_CC60R
Offset
Reset Value
Capture/Compare Register for Channel CC60
34
H
see
15
0
rwh
T12PV
15
0
rh
CCV